Main Cause Analysis
1.Charge mismatch
The ion type of PAM is incompatible with the surface charge of the particles to be treated.
For instance, when anionic PAM treats negatively charged colloidal particles (such as silicates and humic acid), it cannot effectively adsorb them due to electrostatic repulsion.
When cationic PAM is used to treat strongly alkaline (high pH) wastewater, positive charges may be neutralized, reducing the flocculation capacity.
Judgment method: Detect the surface charge of the particles through a Zeta potential meter, or conduct a small-scale test to compare the effects of different ionic types of PAM.
2.The molecular weight is either too high or too low
Excessively high: Ultra-high molecular weight PAM (such as over 20 million) may cause severe entanglement due to overly long chains, thereby reducing the bridging efficiency instead.
Too low: Insufficient molecular weight (such as < If it is 5 million, there will be fewer adsorption sites and it cannot effectively connect particles.
3.The influence of water quality conditions
pH value: Anionic PAM in acidic conditions (pH& LT; 4) Or cationic PAM in alkaline (pH> 10) The effect declines in the environment.
Salt content: High-salt wastewater (such as containing Ca²⁺ and Mg²⁺) may compress the double electric layer, but excessive salt content will shield the active groups of PAM.
Organic matter: Oils or surfactants may coat the particles, hindering the adsorption of PAM.
4.Dissolution or preparation issues
Incomplete dissolution: Clumping or insufficient stirring leads to the failure to release the active ingredients.
Shear degradation: High-speed stirring or centrifugal pumps break the PAM molecular chains, reducing the flocculation property.
Excessive storage time: If the solution is stored for more than 24 hours after dissolution (especially at high temperatures), it may degrade and become ineffective.
5.The dosage is inappropriate
Excessive addition: PAM completely coats the particles, causing them to stabilize again (the "colloid protection" phenomenon), resulting in dispersion rather than flocculation.
Insufficient dosage: Failed to form a sufficient bridging effect.
Solutions
1.Optimize the selection of PAM
Charge matching
Negatively charged particles (such as clay and coal slime) → Select cationic PAM (with an ion degree of 20%-50%).
Positively charged particles (such as metal hydroxides in acidic wastewater) → Select anionic PAM (with a hydrolysis degree of 10%-40%).
For complex water quality (such as oily wastewater) → amphoteric PAM can be tried.
Adjust the molecular weight:
Conventional sewage → Medium molecular weight (8 million -15 million).
High-turbidity wastewater → higher molecular weight (15 million -20 million).
2. Improve water quality conditions
Adjust pH
Anionic PAM is suitable for pH 7-9, while cationic PAM is suitable for pH 5-8. Adjust with acid/alkali when necessary.
Add coagulant aid:
First, add inorganic flocculants (such as PAC, aluminium sulfate) to neutralize the charge, and then use PAM to bridge.
A small amount of CaCl₂ can be added to high-salt wastewater to enhance the charge neutralization effect.
3. Standardize dissolution and addition
Dissolution method:
Use warm water (30-40℃), and slowly sprinkle PAM in to avoid caking.
The stirring speed should be controlled at 200-400 rpm, and the dissolution time is 40-60 minutes.
Addition method:
Multi-point addition: Add in stages in the mixing tank and reaction tank.
Dilution and addition: Dilute the PAM solution to 0.05%-0.1% before use.
4. Experimental verification
Beaker test
Take wastewater samples and test different PAM types (anionic/cationic/nonionic), molecular weights and dosages (0.5-10 ppm) respectively.
Observe the size of the flocs, the sedimentation rate and the turbidity of the supernatant, and select the best solution.